Lines Matching refs:UINT64

53     UINT64  Present:1;                // 0 = Not present in memory, 1 = Present in memory
54 UINT64 ReadWrite:1; // 0 = Read-Only, 1= Read/Write
55 UINT64 UserSupervisor:1; // 0 = Supervisor, 1=User
56 UINT64 WriteThrough:1; // 0 = Write-Back caching, 1=Write-Through caching
57 UINT64 CacheDisabled:1; // 0 = Cached, 1=Non-Cached
58 UINT64 Accessed:1; // 0 = Not accessed, 1 = Accessed (set by CPU)
59 UINT64 Reserved:1; // Reserved
60 UINT64 MustBeZero:2; // Must Be Zero
61 UINT64 Available:3; // Available for use by system software
62 UINT64 PageTableBaseAddress:40; // Page Table Base Address
63 UINT64 AvabilableHigh:11; // Available for use by system software
64 UINT64 Nx:1; // No Execute bit
66 UINT64 Uint64;
74 UINT64 Present:1; // 0 = Not present in memory, 1 = Present in memory
75 UINT64 ReadWrite:1; // 0 = Read-Only, 1= Read/Write
76 UINT64 UserSupervisor:1; // 0 = Supervisor, 1=User
77 UINT64 WriteThrough:1; // 0 = Write-Back caching, 1=Write-Through caching
78 UINT64 CacheDisabled:1; // 0 = Cached, 1=Non-Cached
79 UINT64 Accessed:1; // 0 = Not accessed, 1 = Accessed (set by CPU)
80 UINT64 Dirty:1; // 0 = Not Dirty, 1 = written by processor on access to page
81 UINT64 MustBe1:1; // Must be 1
82UINT64 Global:1; // 0 = Not global page, 1 = global page TLB not cleared on CR3 w…
83 UINT64 Available:3; // Available for use by system software
84 UINT64 PAT:1; //
85 UINT64 MustBeZero:8; // Must be zero;
86 UINT64 PageTableBaseAddress:31; // Page Table Base Address
87 UINT64 AvabilableHigh:11; // Available for use by system software
88 UINT64 Nx:1; // 0 = Execute Code, 1 = No Code Execution
90 UINT64 Uint64;
98 UINT64 Present:1; // 0 = Not present in memory, 1 = Present in memory
99 UINT64 ReadWrite:1; // 0 = Read-Only, 1= Read/Write
100 UINT64 UserSupervisor:1; // 0 = Supervisor, 1=User
101 UINT64 WriteThrough:1; // 0 = Write-Back caching, 1=Write-Through caching
102 UINT64 CacheDisabled:1; // 0 = Cached, 1=Non-Cached
103 UINT64 Accessed:1; // 0 = Not accessed, 1 = Accessed (set by CPU)
104 UINT64 Dirty:1; // 0 = Not Dirty, 1 = written by processor on access to page
105 UINT64 MustBe1:1; // Must be 1
106UINT64 Global:1; // 0 = Not global page, 1 = global page TLB not cleared on CR3 w…
107 UINT64 Available:3; // Available for use by system software
108 UINT64 PAT:1; //
109 UINT64 MustBeZero:17; // Must be zero;
110 UINT64 PageTableBaseAddress:22; // Page Table Base Address
111 UINT64 AvabilableHigh:11; // Available for use by system software
112 UINT64 Nx:1; // 0 = Execute Code, 1 = No Code Execution
114 UINT64 Uint64;